8 practice questions

PD 1096 building code: ALE practice questions

Questions on the National Building Code of the Philippines (PD 1096), such as building permits and what the code requires. Each answer names its source.

Arkitekto is an independent review platform and is not affiliated with, endorsed by, or connected to the Professional Regulation Commission (PRC) or the Professional Regulatory Board of Architecture (PRBoA).

These are practice questions for the ALE, also called the LEA (Licensure Examination for Architects).

Question 1, PD 1096

Under PD 1096, multi-family units averaging above 50 up to 100 sq.m. need how many parking slots?

  1. A.1 slot per 12 units
  2. B.1 slot per 5 units
  3. C.1 slot per 4 units
  4. D.1 slot per 10 units
Show the answer

Answer: C. 1 slot per 4 units

Table VII.4 of the 2004 Revised IRR sets 1 slot per 8 units for units up to 50 sq.m., 1 slot per 4 units above 50 up to 100 sq.m., and 1 slot per unit above 100 sq.m.

Takeaway: Up to 50: 1 per 8. Up to 100: 1 per 4. Above: 1 each.

Source: PD 1096, 2004 Revised IRR, Table VII.4

Question 2, PD 1096

Under PD 1096, a building permit becomes null and void if work has not started within how long from the date of issue?

  1. A.90 days
  2. B.60 days
  3. C.1 year
  4. D.120 days
Show the answer

Answer: C. 1 year

Section 305 voids a permit when work does not start within one year of issue, or when work is suspended or abandoned for 120 days at any time after it starts.

Takeaway: Not started in 1 year, or stopped for 120 days: permit void.

Source: PD 1096, Section 305

Question 3, PD 1096

A bedroom without artificial ventilation measures 3.00 m by 4.00 m. What is the minimum total window opening under PD 1096?

  1. A.1.00 sq.m.
  2. B.1.20 sq.m.
  3. C.1.50 sq.m.
  4. D.2.00 sq.m.
Show the answer

Answer: B. 1.20 sq.m.

Section 808 requires window openings with a free area of at least 10% of the floor area in rooms without artificial ventilation. The room is 12.00 sq.m., so the window needs 1.20 sq.m.

Takeaway: Window openings: at least 10% of the floor area.

Source: PD 1096, Section 808

Question 4, PD 1096

Under the Revised IRR of PD 1096, Rule V covers which topic?

  1. A.Light and Ventilation
  2. B.Requirements of Fire Zones
  3. C.Permits and Inspections
  4. D.Classification and Occupancy
Show the answer

Answer: B. Requirements of Fire Zones

Rule V of the 2004 Revised IRR covers fire zones. Permits and inspection are in Rule III, fire-resistive requirements in Rule VI, classification of buildings by use in Rule VII and light and ventilation in Rule VIII.

Takeaway: Rule V: fire zones. Rule VIII: light and ventilation.

Source: PD 1096, Rule V

Question 5, PD 1096

Under PD 1096, within how many days after final inspection and submittal of the Certificate of Completion must the Certificate of Occupancy be issued?

  1. A.30 days
  2. B.15 days
  3. C.60 days
  4. D.45 days
Show the answer

Answer: A. 30 days

Section 309 requires the Building Official to issue the Certificate of Occupancy within 30 days after the final inspection and submittal of a Certificate of Completion.

Takeaway: Certificate of Occupancy: within 30 days.

Source: PD 1096, Section 309

Question 6, PD 1096

Under PD 1096, Group J buildings are classified as:

  1. A.Industrial
  2. B.Accessory
  3. C.Assembly other than Group I
  4. D.Storage and hazardous
Show the answer

Answer: B. Accessory

Section 701 designates Group J as Accessory. It covers agricultural structures such as barns and sheds, and private garages and carports.

Takeaway: Group J: accessory buildings.

Source: PD 1096, Section 701

Question 7, PD 1096

Under the Revised IRR of PD 1096, Rule VIII covers which topic?

  1. A.Light and Ventilation
  2. B.Fire-Resistive Standards
  3. C.Sanitation
  4. D.Permits and Inspections
Show the answer

Answer: A. Light and Ventilation

Rule VIII of the 2004 Revised IRR covers light and ventilation: site occupancy, courts, ceiling heights, room sizes, air space, window openings and vent shafts. Sanitation is Rule IX.

Takeaway: Rule VIII: light and ventilation. Rule IX: sanitation.

Source: PD 1096, Rule VIII

Question 8, PD 1096

Under PD 1096, in other than Type V construction, a penthouse enclosing tanks or elevators that run to the roof may extend at most how high above the roof?

  1. A.3.60 m
  2. B.8.40 m
  3. C.10.00 m
  4. D.6.00 m
Show the answer

Answer: B. 8.40 m

Section 1210 limits such penthouses to 8.40 m above the roof when they enclose tanks or elevators running to the roof. In all other cases the limit is 3.60 m.

Takeaway: Tank or elevator penthouse: 8.40 m. Others: 3.60 m.

Source: PD 1096, Section 1210

Back to all ALE practice questions.